Xu, Yongjia, Gao, Feng, Zhang, Zonghua and Jiang, Xiang (2017) A calibration method for non-overlapping cameras based on mirrored phase target. In: The 13th International Symposium on Measurement Technology and Intelligent Instruments, 22-25 September 2017, Xi'an, Shaanxi, China. (Unpublished)
Abstract

A novel calibration method for non-overlapping cameras is proposed in this paper. A LCD screen is used as a phase target to display two groups of orthogonal phase-shifted sinusoidal patterns during the calibration process. Through a mirror reflection, the phase target is captured by the cameras respectively. The relations between each camera and the phase target can be obtained according the proposed algorithm. Then the relation between the cameras can be calculated by treating the phase target as an intermediate value. The proposed method is more flexible than conventional mirror-based approach, because it do not require the common identification points and is robust to out-of-focus images. Both simulation work and experimental results show the proposed calibration method has a good result in calibrating a non-overlapping cameras system.