Jaber, Adel, Lazaridis, Pavlos, Saeed, Bakhtiar I., Mather, Peter, Vieira, M F Q, Atkinson, R., Tachtatzis, Christos, Iorkyase, E. T., Judd, M and Glover, Ian (2017) Diagnostic Potential of Free-Space Radiometric Partial Discharge Measurements. In: URSI GASS 2017, 19-26 August 2017, Montreal, Canada.
Abstract

The work reported in this paper addresses the calibration of four types of partial discharge (PD) emulator required for the development of a PD Wireless Sensor Network (WSN). Three partial discharge (PD) emulators have been constructed: a floating-electrode emulator, and two internal
PD emulators. Both DC and AC HV power supplies are used to initiate PD which is measured using concurrent free-space radiometry (FSR) and a galvanic contact method based on the IEC 60270 standard. A new method of estimating absolute PD activity level from a radiometric measurement is proposed.

Information
Library
Documents
[thumbnail of Paper_C2-1(2675).pdf]
Preview
Paper_C2-1(2675).pdf - Accepted Version

Download (2MB) | Preview
Statistics

Downloads

Downloads per month over past year

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email