Murray, C..D., Rahman, R. and Stephenson, John (2012) Iatrogenic Retinal Breaks Induced by Separation of Posterior Hyaloid Face during 23-Gauge Pars Plana Vitrectomy. In: European Society of Retina Specialists 12th EURETINA Congress 2012, 6 - 9 September 2012, Milan, Italy. (Unpublished)
Abstract

Describe incidence and features of intraoperative retinal breaks caused by iatrogenic separation of the posterior hyaloid face (PHF) during 23-G Pars Plana Vitrectomy (PPV) surgery for:

Macula hole (MH)
Vitreomacula traction (VMT)
Epiretinal membrane (ERM)
Floaters

Library
Documents
[thumbnail of StephensonEURETINA_23G_IATROGENIC_BREAKS_FROM_PHF_INDUCTION.pdf]
Preview
StephensonEURETINA_23G_IATROGENIC_BREAKS_FROM_PHF_INDUCTION.pdf - Presentation

Download (409kB) | Preview
[thumbnail of StephensonEURETINA_23G_IATROGENIC_BREAKS_FROM_PHF_INDUCTION.pptx]
StephensonEURETINA_23G_IATROGENIC_BREAKS_FROM_PHF_INDUCTION.pptx - Presentation

Download (129kB)
Statistics

Downloads

Downloads per month over past year

Downloads per month over past year for
"StephensonEURETINA_23G_IATROGENIC_BREAKS_FROM_PHF_INDUCTION.pdf"

Downloads per month over past year for
"StephensonEURETINA_23G_IATROGENIC_BREAKS_FROM_PHF_INDUCTION.pptx"

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email