Muller, M and Barrans, Simon (2009) Ultimate axial load capacity of v-band clamp joints. In: Proceedings of Computing and Engineering Annual Researchers' Conference 2009: CEARC’09. University of Huddersfield, Huddersfield, pp. 14-18. ISBN 9781862180857
Abstract

Band clamps with a flat bottomed V-section are used to connect a pair of circular flanges to provide a joint with significant axial strength. Despite the wide application of V-band clamps, their behaviour is not fully understood and the ultimate axial strength is currently only available from physical testing. This physical testing has indicated that the ultimate strength is determined by two different types of structural deformation, an elastic deformation mode and a plastic deformation mode. Initial finite element analysis work has demonstrated that analysis of this class of problem is not straightforward. This paper discusses the difficulties encountered when simulating this type of component interaction where contact is highly localised and contact pressures are high and therefore presents a finite element model to predict the ultimate axial load capacity of V-band clamps.

Library
Documents
[img]
Preview
3_M_Muller.pdf - Published Version

Download (343kB) | Preview
Statistics

Downloads

Downloads per month over past year

Add to AnyAdd to TwitterAdd to FacebookAdd to LinkedinAdd to PinterestAdd to Email