Search:
Computing and Library Services - delivering an inspiring information environment

A Revised Design for Microarray Experiments to Account for Experimental Noise and Uncertainty of Probe Response

Kaderali, Lars, Pozhitkov, Alex E., Noble, Peter A., Bryk, Jarek and Tautz, Diethard (2014) A Revised Design for Microarray Experiments to Account for Experimental Noise and Uncertainty of Probe Response. PLoS ONE, 9 (3). e91295. ISSN 1932-6203

[img]
Preview
PDF - Published Version
Available under License Creative Commons Attribution.

Download (1MB) | Preview

Abstract

Background

Although microarrays are analysis tools in biomedical research, they are known to yield noisy output that usually requires experimental confirmation. To tackle this problem, many studies have developed rules for optimizing probe design and devised complex statistical tools to analyze the output. However, less emphasis has been placed on systematically identifying the noise component as part of the experimental procedure. One source of noise is the variance in probe binding, which can be assessed by replicating array probes. The second source is poor probe performance, which can be assessed by calibrating the array based on a dilution series of target molecules. Using model experiments for copy number variation and gene expression measurements, we investigate here a revised design for microarray experiments that addresses both of these sources of variance.

Results

Two custom arrays were used to evaluate the revised design: one based on 25 mer probes from an Affymetrix design and the other based on 60 mer probes from an Agilent design. To assess experimental variance in probe binding, all probes were replicated ten times. To assess probe performance, the probes were calibrated using a dilution series of target molecules and the signal response was fitted to an adsorption model. We found that significant variance of the signal could be controlled by averaging across probes and removing probes that are nonresponsive or poorly responsive in the calibration experiment. Taking this into account, one can obtain a more reliable signal with the added option of obtaining absolute rather than relative measurements.

Conclusion

The assessment of technical variance within the experiments, combined with the calibration of probes allows to remove poorly responding probes and yields more reliable signals for the remaining ones. Once an array is properly calibrated, absolute quantification of signals becomes straight forward, alleviating the need for normalization and reference hybridizations.

Item Type: Article
Subjects: Q Science > Q Science (General)
Q Science > QH Natural history > QH301 Biology
Schools: School of Applied Sciences
Related URLs:
Depositing User: Sara Taylor
Date Deposited: 08 Sep 2015 14:30
Last Modified: 02 Dec 2016 05:51
URI: http://eprints.hud.ac.uk/id/eprint/25622

Downloads

Downloads per month over past year

Repository Staff Only: item control page

View Item View Item

University of Huddersfield, Queensgate, Huddersfield, HD1 3DH Copyright and Disclaimer All rights reserved ©