Murray, C..D., Rahman, R. and Stephenson, John (2012) Iatrogenic Retinal Breaks Induced by Separation of Posterior Hyaloid Face during 23-Gauge Pars Plana Vitrectomy. In: European Society of Retina Specialists 12th EURETINA Congress 2012, 6 - 9 September 2012, Milan, Italy. (Unpublished)
Abstract

Describe incidence and features of intraoperative retinal breaks caused by iatrogenic separation of the posterior hyaloid face (PHF) during 23-G Pars Plana Vitrectomy (PPV) surgery for:

Macula hole (MH)
Vitreomacula traction (VMT)
Epiretinal membrane (ERM)
Floaters