Search:
Computing and Library Services - delivering an inspiring information environment

Optimisation of a Voltage Measurement and Control Circuit for an Imaging Electromagnetic Flow Meter

Ali, M. and Lucas, Gary (2012) Optimisation of a Voltage Measurement and Control Circuit for an Imaging Electromagnetic Flow Meter. In: Proceedings of The Queen’s Diamond Jubilee Computing and Engineering Annual Researchers’ Conference 2012: CEARC’12. University of Huddersfield, Huddersfield, pp. 45-50. ISBN 978-1-86218-106-9

[img]
Preview
PDF (Cover page)
Cover_pages.pdf - Published Version

Download (1MB) | Preview
[img]
Preview
PDF
M_Ali_Paper.pdf - Published Version

Download (214kB) | Preview

Abstract

This paper describes the optimisations conducted on an existing voltage measurement and control
circuit to allow its use in a novel imaging electromagnetic flow meter. This flow meter is a multielectrode device that can construct a velocity profile in both single and multiphase flow applications. Voltages are induced in the fluid flowing through the flow meter section due to the interaction of the fluid and the locally generated magnetic field. These voltages are detected by an array of electrodes and measured by a 7-channel system, based on the voltage measurement and control circuit. Each channel measures the potential difference between two electrodes in the flow cross section. The voltage measurement and control circuit comprises a very high amplification stage and an integral controller. The amplification stage is required to amplify the induced voltages of mV to V, suitable for analogue-to-digital conversion. The integral controller acts to eliminate the DC error component introduced in the amplification stage to prevent the circuit from exceeding its operational dynamic range limit. The existing voltage measurement and control circuit design has several drawbacks. The very high amplification stage occasionally causes the circuit to exceed its operational dynamic range.
In addition, the integral controller has a slow action response which results in a long settling time and offset error. These drawbacks were overcome in the optimised design - discussed in this paper.

Item Type: Book Chapter
Uncontrolled Keywords: electromagnetic, flow meter, induced voltage, multi electrode, DC error component
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Schools: School of Computing and Engineering
School of Computing and Engineering > Computing and Engineering Annual Researchers' Conference (CEARC)
School of Computing and Engineering > High-Performance Intelligent Computing > High Performance Computing Research Group
School of Computing and Engineering > Systems Engineering Research Group
Related URLs:
Depositing User: Sharon Beastall
Date Deposited: 01 May 2012 08:43
Last Modified: 01 May 2012 08:43
URI: http://eprints.hud.ac.uk/id/eprint/13446

Downloads

Downloads per month over past year

Repository Staff Only: item control page